Mouse/Rat Von Willebrand Factor/vWF enzyme-linked immunoassay kit(one step)

CAT: EMY0079 Datasheet
Specification 96 Test
Sensitivity 0.07 ng/ml (10 μl)
Standard Curve Range 15.63~1000 pg/ml
Standard Curve Gradient 7 Points
Number of Incubations 1
Detectable sample serum, plasma
Sample Volume 10 μl
Type Fully Ready-to-Use
Operation Duration 60min
ng/ml O.D. Average Corrected
0.00 0.0087 0.0089 0.0088
15.63 0.0551 0.0542 0.0547 0.0459
31.25 0.1052 0.1039 0.1046 0.0958
62.50 0.1997 0.2040 0.2019 0.1931
125.00 0.4026 0.4122 0.4074 0.3986
250.00 0.7606 0.8061 0.7834 0.7746
500.00 1.4480 1.4910 1.4695 1.4607
1000.00 2.5890 2.5310 2.5600 2.5512

Precision

Intra-assay Precision Inter-assay Precision
Sample Number S1 S2 S3 S1 S2 S3
22 22 22 6 6 6
Average(ng/ml) 20.7 97.2 277.5 19.5 93.1 274.8
Standard Deviation 0.9 4.8 10.3 0.9 4.2 12.6
Coefficient of Variation(%) 4.6 5.0 3.7 4.6 4.5 4.6

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty-two times on one plate to assess intra-assay precision. Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.

Spike Recovery

The spike recovery was evaluated by spiking 3 levels of mouse/rat Von Willebrand Factor/vWF into health mouse/rat serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 80% to 120% with an overall mean recovery of 108%.

Sample Values

Sample Matrix Sample Evaluated Range (ng/ml) Detectable (%) Mean of Detectable (ng/ml)
Mouse Serum3058.63-152.0010080.70
Rat Serum30179.60-432.13100268.37

Serum/Plasma – Thirty samples from apparently healthy mice and thirty samples from apparently healthy rats were evaluated for the presence of mouse/rat Von Willebrand Factor/vWF in this assay. No medical histories were available for the donors. n.d. = non-detectable. Samples measured below the sensitivity are considered to be non-detectable.

Background: Von Willebrand Factor/vWF

The glycoprotein encoded by this gene functions as both an antihemophilic factor carrier and a platelet-vessel wall mediator in the blood coagulation system. It is crucial to the hemostasis process. Mutations in this gene or deficiencies in this protein result in von Willebrand's disease. An unprocessed pseudogene has been found on chromosome 22.

Under construction!

Under construction!

Under construction!

Contact Information
Related Products
相关途径
Guarantee