Human Renin ELISA Kit检测试剂盒
| 规格 | 96 Test |
|---|---|
| 灵敏度 | 0.08 pg/ml (50 μl);0.25 pg/ml (10 μl); |
| 标准曲线范围 | 2.74~2000 pg/ml |
| 标准曲线梯度 | 7点/3倍 |
| 孵育次数 | 2 |
| 可检测样本 | 可溶性物质的液相样品。例如:血清,血浆,细胞培养上清,组织研磨液等。 |
| 加样体积 | 50 μl/10 μl |
| 类型 | 即用型 |
| 操作时长 | 120min |
| pg/ml | O.D. | Average | Corrected | |
|---|---|---|---|---|
| 0.00 | 0.0078 | 0.0077 | 0.0077 | |
| 2.74 | 0.0338 | 0.0321 | 0.0330 | 0.0253 |
| 8.23 | 0.0883 | 0.0978 | 0.0931 | 0.0854 |
| 24.69 | 0.2698 | 0.2577 | 0.2638 | 0.2561 |
| 74.07 | 0.7291 | 0.6849 | 0.7070 | 0.6993 |
| 222.22 | 1.7700 | 1.6890 | 1.7295 | 1.7218 |
| 666.67 | 3.1820 | 3.0870 | 3.1345 | 3.1268 |
| 2000.00 | 4.1599 | 4.1959 | 4.1779 | 4.1702 |
精度
| Intra-assay Precision | Inter-assay Precision | |||||
| Sample Number | S1 | S2 | S3 | S1 | S2 | S3 |
| 22 | 22 | 22 | 6 | 6 | 6 | |
| Average(pg/ml) | 36.2 | 188.8 | 754.8 | 37.5 | 191.8 | 651.7 |
| Standard Deviation | 1.0 | 8.4 | 29.6 | 1.7 | 5.8 | 17.0 |
| Coefficient of Variation(%) | 2.8 | 4.4 | 3.9 | 4.6 | 3.0 | 2.6 |
板内精密度:3 个已知浓度的样本酶标板内重复测定 20 次,评估酶标板内的精密度。
板间精密度:3 个已知浓度的样本酶标板间重复检测 6 次,评估酶标板间的精密度。
加标回收
健康人血清加入 3 个不同浓度水平的人Renin,未加人 Renin 的血清作为本底,计算回收率。回收率的范围从 85 % 至 120 %,平均回收率为 106 %。
样本值
| Sample Matrix | Sample Evaluated | Range (pg/ml) | Detectable (%) | Mean of Detectable (pg/ml) |
|---|---|---|---|---|
| Serum | 30 | 415.85-1298.17 | 100 | 791.38 |
应用本试剂盒,检测 30 个健康志愿者的血清样本,志愿者的用药史不详。n.d. = 测不到浓度值。样本的浓度值低于灵敏度被认为测不到浓度值。
产品数据表
背景: Renin
肾素是一种分泌的内肽酶,通过血管紧张剂的切割调节血压和盐分平衡发挥关键作用,而血管紧张素原是肾素唯一的已知生理底物。406 aa前体包括信号肽(AA 1 - 23)、丙肽(AA 24 - 66)和成熟链(AA 67 - 406)。人类肾素的氨基酸串行与黑猩猩、犬类、小鼠和大鼠的氨基酸串行分别为100%、73%、71%和67%。
小鼠肾素是肽酶A1家族中分泌的糖基化成员,容量为42至47 kDa。它是一种天氨酸蛋白酶,能切割血管紧张素原形成血管紧张素I。在小鼠中,有两个基因编码Renin。一个在下颌下腺,另一个在肾脏。两种成熟的肾素分子氨基酸(aa)含量95%。肾肾素(Renin-1)合成为381 aa蛋白体(AA 22 - 402)。在肾脏中,前雷腺素在Thr71后被蛋白水解切割,生成成熟酶。小鼠前肾素在抗抗体串行上分别与人类和大鼠的前雷素共享70%和85%。