Human CCL20/MIP-3 alpha ELISA Kit检测试剂盒
规格 | 96 Test |
---|---|
灵敏度 | 8.58 pg/ml (50 μl);12.19 pg/ml (10 μl) |
标准曲线范围 | 10.97~8000 pg/ml |
标准曲线梯度 | 7点/3倍 |
孵育次数 | 2 |
加样体积 | 50 μl/10 μl |
类型 | 完全即用型 |
操作时长 | 120min |
pg/ml | O.D. | Average | Corrected | |
---|---|---|---|---|
0.00 | 0.0175 | 0.0195 | 0.0185 | |
10.97 | 0.0264 | 0.0238 | 0.0251 | 0.0066 |
32.92 | 0.0320 | 0.0311 | 0.0316 | 0.0131 |
98.77 | 0.0640 | 0.0629 | 0.0635 | 0.0450 |
296.30 | 0.2220 | 0.2240 | 0.2230 | 0.2045 |
888.89 | 0.9390 | 0.9138 | 0.9264 | 0.9079 |
2666.67 | 2.4702 | 2.4450 | 2.4576 | 2.4391 |
8000.00 | 3.9750 | 4.0220 | 3.9985 | 3.9800 |
精度
Intra-assay Precision | Inter-assay Precision | |||||
Sample Number | S1 | S2 | S3 | S1 | S2 | S3 |
22 | 22 | 22 | 6 | 6 | 6 | |
Average(pg/ml) | 78.1 | 395.8 | 1027.1 | 82.4 | 379.2 | 1127.4 |
Standard Deviation | 2.4 | 14.8 | 30.9 | 4.2 | 24.1 | 74.6 |
Coefficient of Variation(%) | 3.1 | 3.7 | 3.0 | 4.0 | 6.4 | 6.6 |
板内精密度:3 个已知浓度的样本酶标板内重复测定 20 次,评估酶标板内的精密度。
板间精密度:3 个已知浓度的样本酶标板间重复检测 6 次,评估酶标板间的精密度。
加标回收
健康人血清加入 3 个不同浓度水平的人CCL20,未加人 CCL20 的血清作为本底,计算回收率。回收率的范围从 121 % 至 128 %,平均回收率为 115 %。
样本值
Sample Matrix | Sample Evaluated | Range (pg/ml) | Detectable (%) | Mean of Detectable (pg/ml) |
---|---|---|---|---|
Serum | 30 | n.d.-67.43 | 20 | 39.61 |
应用本试剂盒,检测 30 个健康志愿者的血清样本,志愿者的用药史不详。n.d. = 测不到浓度值。样本的浓度值低于灵敏度被认为测不到浓度值。
产品数据表
背景: CCL20/MIP-3 alpha
CCL20,也称为MIP-3α,是一种趋化因子,在树突状细胞运输和T细胞的募集和活化中起重要作用。炎症刺激后,它在单核细胞、T 细胞、内皮细胞、上皮细胞和成纤维细胞中上调。CCL20通过CCR6发出信号,CCR6在记忆T细胞,B细胞和骨髓来源的树突状细胞上表达。