Human CCL18/PARC/MIP-4 ELISA Kit检测试剂盒
| 规格 | 96 Test |
|---|---|
| 灵敏度 | 0.13 pg/ml (50 μl);7.26 pg/ml (10 μl); |
| 标准曲线范围 | 15.63 ~1000 pg/ml |
| 标准曲线梯度 | 7点 |
| 孵育次数 | 2 |
| 可检测样本 | 可溶性物质的液相样品。例如:血清,血浆,细胞培养上清,组织研磨液等。 |
| 加样体积 | 50 μl/10 μl |
| 类型 | 完全即用型 |
| 操作时长 | 120min |
| pg/ml | O.D. | Average | Corrected | |
|---|---|---|---|---|
| 0.00 | 0.0386 | 0.0375 | 0.0381 | |
| 15.63 | 0.1236 | 0.1275 | 0.1256 | 0.0875 |
| 31.25 | 0.2108 | 0.2100 | 0.2104 | 0.1724 |
| 62.50 | 0.3804 | 0.3785 | 0.3795 | 0.3414 |
| 125.00 | 0.6842 | 0.6825 | 0.6834 | 0.6453 |
| 250.00 | 1.2560 | 1.3060 | 1.2810 | 1.2430 |
| 500.00 | 2.1770 | 2.2180 | 2.1975 | 2.1595 |
| 1000.00 | 3.1250 | 3.1780 | 3.1515 | 3.1135 |
精度
| Intra-assay Precision | Inter-assay Precision | |||||
| Sample Number | S1 | S2 | S3 | S1 | S2 | S3 |
| 22 | 22 | 22 | 6 | 6 | 6 | |
| Average(pg/ml) | 42.2 | 224.5 | 753.7 | 43.6 | 199.5 | 614.8 |
| Standard Deviation | 1.5 | 7.7 | 34.5 | 1.8 | 6.2 | 29.3 |
| Coefficient of Variation(%) | 3.5 | 3.4 | 4.6 | 4.1 | 3.1 | 4.8 |
板内精密度:3 个已知浓度的样本酶标板内重复测定 22 次,评估酶标板内的精密度。
板间精密度:3 个已知浓度的样本酶标板间重复检测 6 次,评估酶标板间的精密度。
加标回收
健康人血清加入3个不同浓度水平的人CCL18/PARC/MIP-4,未加入人CCL18/PARC/MIP-4的血清作为本底,计算回收率。
回收率的范围从92%至109%,平均回收率为101%。
样本值
| Sample Matrix | Sample Evaluated | Range (ng/ml) | Detectable (%) | Mean of Detectable (ng/ml) |
|---|---|---|---|---|
| Serum | 30 | 7.85-29.14 | 100 | 18.17 |
应用本试剂盒,检测30份健康志愿者的血清样本。
n.d. =测不到浓度值。样本的浓度值低于灵敏度被认为测不到浓度值。
产品数据表
背景: CCL18/PARC/MIP-4
肺部及激活调控趋化因子(PARC),也称为替代巨噬细胞激活相关CC趋化因子(AMAC)-1、巨噬细胞炎症蛋白(MIP)-4和树突细胞趋化因子(DC-CK1),是一种新型CC趋化因子,与MIP-1 α高度同源(氨基酸串行同源度为61%)。体外实验中,PARC mRNA表达由Th2细胞因子如IL-4、IL-10和IL-13诱导,并在IFN-γ中抑制。